| Server IP : 127.0.1.1 / Your IP : 216.73.216.152 Web Server : Apache/2.4.52 (Ubuntu) System : Linux bahcrestlinepropertiesllc 5.15.0-113-generic #123-Ubuntu SMP Mon Jun 10 08:16:17 UTC 2024 x86_64 User : www-data ( 33) PHP Version : 7.4.33 Disable Function : pcntl_alarm,pcntl_fork,pcntl_waitpid,pcntl_wait,pcntl_wifexited,pcntl_wifstopped,pcntl_wifsignaled,pcntl_wifcontinued,pcntl_wexitstatus,pcntl_wtermsig,pcntl_wstopsig,pcntl_signal,pcntl_signal_get_handler,pcntl_signal_dispatch,pcntl_get_last_error,pcntl_strerror,pcntl_sigprocmask,pcntl_sigwaitinfo,pcntl_sigtimedwait,pcntl_exec,pcntl_getpriority,pcntl_setpriority,pcntl_async_signals,pcntl_unshare, MySQL : OFF | cURL : ON | WGET : ON | Perl : ON | Python : OFF | Sudo : ON | Pkexec : ON Directory : /proc/thread-self/root/usr/share/initramfs-tools/hooks/ |
Upload File : |
#!/bin/sh
#
# Copyright © 2006-2008 Martin F. Krafft <madduck@debian.org>,
# 2012 Michael Tokarev <mjt@tls.msk.ru>
# based on the scripts in the initramfs-tools package.
# released under the terms of the Artistic Licence.
#
set -eu
PREREQ="udev"
prereqs()
{
echo "$PREREQ"
}
case "${1:-}" in
prereqs)
prereqs
exit 0
;;
esac
is_true()
{
case "${1:-}" in
[Yy]es|[Yy]|1|[Tt]rue|[Tt]) return 0;;
*) return 1;;
esac
}
write()
{
local PREFIX; PREFIX=$1; shift
echo "${PREFIX}: mdadm: $@" >&2
}
info()
{
is_true ${VERBOSE:-false} && write I "$@" || :
}
warn()
{
write W "$@"
}
. /usr/share/initramfs-tools/hook-functions
# copy the binary as early as possible
copy_exec /sbin/mdadm /sbin
copy_exec /sbin/mdmon /sbin
# Copy udev rules, which udev no longer does
for UDEV_RULE in 63-md-raid-arrays.rules 64-md-raid-assembly.rules; do
for rules_folder in /lib/udev/rules.d /etc/udev/rules.d; do
if [ -f $rules_folder/$UDEV_RULE ]; then
mkdir -p $DESTDIR$rules_folder
cp $rules_folder/$UDEV_RULE $DESTDIR$rules_folder/$UDEV_RULE
fi
done
done
# load raid modules in the initramfs
for module in linear multipath raid0 raid1 raid456 raid5 raid6 raid10; do
force_load $module
done
# load efivars for Intel RST IMSM, see Bug#962844
force_load efivars || true
# copy the mdadm configuration
CONFIG=/etc/mdadm/mdadm.conf
ALTCONFIG=/etc/mdadm.conf
DESTMDADMCONF=$DESTDIR/etc/mdadm/mdadm.conf
[ ! -f $CONFIG ] && [ -f $ALTCONFIG ] && CONFIG=$ALTCONFIG || :
mkdir -p ${DESTDIR}/etc/mdadm
if [ ! -f $CONFIG ]; then
# there is no configuration file, so let's create one
if /usr/share/mdadm/mkconf generate $CONFIG; then
# all is well
cp -p $CONFIG $DESTMDADMCONF
info "auto-generated the mdadm.conf configuration file."
else
# we failed to auto-generate, so let the emergency procedure take over
warn "failed to auto-generate the mdadm.conf file."
warn "please read /usr/share/doc/mdadm/README.upgrading-2.5.3.gz ."
fi
else
cp -p $CONFIG ${DESTDIR}/etc/mdadm
sed -i '/^CREATE/s/^/#/' $DESTMDADMCONF
if ! grep -q '^ARRAY' $CONFIG; then
tmpfile="${DESTMDADMCONF}.tmp"
if /usr/share/mdadm/mkconf > $tmpfile; then
cp -p $tmpfile $DESTMDADMCONF
else
warn "failed to auto-generate temporary mdadm.conf file."
fi
else
# make sure the configuration file knows about all running devices
/sbin/mdadm --detail --scan | while read array device params; do
uuid=${params#*UUID=}; uuid=${uuid%% *}
if grep -qi "UUID=$uuid" $DESTMDADMCONF; then
info "$uuid $device added to the mdadm.conf in the initramfs"
fi
done
fi
fi